B01: 16′

Request a quote Build the wall on paper first. Number the pieces, compare the stock, then carry the same framing into your drywall plan.
Framing plan
16′ overall · flat wall · heights 8′ / 8′ · 16″ O.C., first centre 16″ · actual 1.5 × 3.5 in · 1 bottom / 2 top plates · end packs 1 / 1 · 0.125″ kerf · 10% spares
Tap a piece or choose it from the numbered schedule. Small member labels stay in the schedule to keep the opening details clear.
F01 Common stud
- Left face from wall datum
- 15.25″
- Centre from wall datum
- 16″
- Bottom above floor
- 1.5″
- Stock assignment
- L6
Top marks: 0″ across the stud face → 91.5″ from its bottom · 1.5″ across the stud face → 91.5″ from its bottom.
Ready to board this wall?
Transfer the profile, openings and actual framing supports into the drywall planner.
Numbered member schedule 16 marks
Face and centre stations are from the wall’s left edge. Lengths are blank lengths rounded up to 1/16″. Transfer the exact cut marks and check final fit.
| Mark / member | Position from left | Cut / quantity |
|---|---|---|
| End stud | Face 0″Centre 0.75″Bottom 1.5″ above floor | 7′ 7 1/2″ × 1 |
| End stud | Face 190.5″Centre 191.25″Bottom 1.5″ above floor | 7′ 7 1/2″ × 1 |
| Common stud | Face 15.25″Centre 16″Bottom 1.5″ above floor | 7′ 7 1/2″ × 1 |
| Common stud | Face 31.25″Centre 32″Bottom 1.5″ above floor | 7′ 7 1/2″ × 1 |
| Common stud | Face 47.25″Centre 48″Bottom 1.5″ above floor | 7′ 7 1/2″ × 1 |
| Common stud | Face 63.25″Centre 64″Bottom 1.5″ above floor | 7′ 7 1/2″ × 1 |
| Common stud | Face 79.25″Centre 80″Bottom 1.5″ above floor | 7′ 7 1/2″ × 1 |
| Common stud | Face 95.25″Centre 96″Bottom 1.5″ above floor | 7′ 7 1/2″ × 1 |
| Common stud | Face 111.25″Centre 112″Bottom 1.5″ above floor | 7′ 7 1/2″ × 1 |
| Common stud | Face 127.25″Centre 128″Bottom 1.5″ above floor | 7′ 7 1/2″ × 1 |
| Common stud | Face 143.25″Centre 144″Bottom 1.5″ above floor | 7′ 7 1/2″ × 1 |
| Common stud | Face 159.25″Centre 160″Bottom 1.5″ above floor | 7′ 7 1/2″ × 1 |
| Common stud | Face 175.25″Centre 176″Bottom 1.5″ above floor | 7′ 7 1/2″ × 1 |
| Top plateLayer 1; blank measured along the board, including angled ends. Transfer the end shape from the wall profile. | Face 0″Bottom 94.5″ above floor | 16′ × 1 |
| Top plateLayer 2; blank measured along the board, including angled ends. Transfer the end shape from the wall profile. | Face 0″Bottom 93″ above floor | 16′ × 1 |
| Bottom plateLayer 1; includes plate through door openings for assembly. Remove door sections after erection. | Face 0″Bottom 0″ above floor | 16′ × 1 |
Stock boards & cutting order 18 boards
Each L-number is one stock board. Cut left to right in the listed order; kerf is included. 4′ 8 7/8″ of length offcuts remain across all profiles, excluding spare boards. Square-end trimming and defects need your field allowance.
Main framing · 1.5 × 3.5 in actual
15 × 8′ · 3 × 16′
T01: 16′
T02: 16′
E01: 7′ 7 1/2″
E02: 7′ 7 1/2″
F01: 7′ 7 1/2″
F02: 7′ 7 1/2″
F03: 7′ 7 1/2″
F04: 7′ 7 1/2″
F05: 7′ 7 1/2″
F06: 7′ 7 1/2″
F07: 7′ 7 1/2″
F08: 7′ 7 1/2″
F09: 7′ 7 1/2″
F10: 7′ 7 1/2″
F11: 7′ 7 1/2″
Keep this board uncut for field changes or defects.
Keep this board uncut for field changes or defects.
Compare purchasing options
Plate splices are recalculated for each stock length. Studs and headers remain single pieces. These are practical packing comparisons; they do not prove a global minimum.
Before ordering or cutting
This is a layout and lumber takeoff. Enter header sizes, stud spacing, plate layers and support counts from the framing detail for your project. Structural capacity and fastening are not calculated.
- Headers use the selected actual depth and ply count. Engineered headers, steel, hangers, blocking, fire stops, sheathing and corner returns require separate quantities.
- Verify field dimensions, straight stock and the specified connections before using the cut list.
Same wall. Next trade.
Frame it once.
Plan the finish.
Cut lengths follow the actual profile
Sloped plates retain their true thickness perpendicular to the board. Studs beneath them have distinct long and short points; a stud crossing a gable peak keeps both top angles.
Openings change the support grid
Kings, jacks, headers, sills and cripples replace the repeating studs around each opening. The drywall handoff checks vertical joints against these actual support lengths, including gaps through the opening.
Use the specified framing detail
This version models built-up solid-lumber headers and packed wall ends in elevation. Shared opening packs, engineered header products, bracing, intersecting walls and load design need their own detail.
Open the drywall plannerFraming field guides
From the wall line to the cut list.
Measure the overall frame, enter the specified opening details, and check the layout before ordering or cutting.
Measure the frame and openings
Set a common datum, actual lumber sizes and clear rough-opening dimensions.
Read guideRead the framing and lumber lists
Transfer centre marks, sloped cuts and numbered stock assignments.
Read guideCarry the framing into drywall
Use the same wall and check joints against the real support lengths.
Read guide